WIP: Not working

This commit is contained in:
Alexandre Simao 2021-06-30 16:40:57 +02:00
parent 2c0128c26b
commit 5ac206d370
3 changed files with 65 additions and 206 deletions

View File

@ -8,12 +8,13 @@ echo "GPLv3"
$base_cli = Read-Host "CLI base disk name with extension?"
$base_srv = Read-Host "SRV base disk name with extension?"
$base_vhd_path = "${vhd_path}Base\"
$scripts_path = Read-host "Scripts path with trailling slash?"
$soft_path = Read-host "Software directory with trailing slash?"
$scripts_path = Read-host "Scripts path with trailing slash?"
$source_cli_name = Read-Host "CLI source disk name with extension?"
$source_path = Read-host "Actual source path with trailling slash?"
$source_path = Read-host "Actual source path with trailing slash?"
$source_srv_name = Read-Host "SRV source disk name with extension?"
$vhd_path = Read-host "VHD path with trailling slash?"
$vm_path = Read-Host "VM path with trailling slash?"
$vhd_path = Read-host "VHD path with trailing slash?"
$vm_path = Read-Host "VM path with trailing slash?"
### Store them as ENV vars

View File

@ -3,216 +3,74 @@
echo "Shamefully made by Alexandre Simao. Pardon-me dear M. Stallman"
echo "GPLv3"
### Considered as finished. Need improvement VM side.
$VM_list= import-csv ./VM_list.csv
$VM_list= import-csv ./VM_list.csv -delimiter ","
$i = 0
$j = 1
foreach ($VM_list.VM_name in $VM_list) {
$VM_Name = $VM_list.VM_name
$Switch_name = $VM_list.Switch_name
$Switch_name2 = $VM_list.Switch_name2
$Switch_Name3 = $VM_list.Switch_name3
$Gen = $VM_list.Gen
$Min_mem = $VM_list.Min_mem
$Mem = $VM_list.Min_mem
$Max_mem = $VM_list.Max_mem
$CPUs = $VM_list.Max_mem
echo "Adding and configuring ($VM_list.VM_Name[$i])";
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1;
$DriveLetter = $Lettre.DriveLetter;
$drive = $DriveLetter + ":";
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory";
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml";
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd";
mkdir "${Driveletter}:\Tools\Scripts";
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1";
foreach ($VM in $VM_list) {
echo "Adding and configuring ($VM_List.VM_Name[$i])";
if ( ($VM.VM_name[$i]) -Like "SRV*") {
Copy-Item "${env:BASE_VHD_PATH}${env:BASE_SRV}" "${env:VHD_PATH}${VM_NAME}.vhdx"
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1;
$DriveLetter = $Lettre.DriveLetter;
$drive = $DriveLetter + ":";
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory";
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml";
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd";
mkdir "${Drive}\Tools\Scripts";
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1";
Dismount-VHD "$env:VHD_PATH($VM.VM_name[$i]).vhdx";
New-VM -Name "($VM.VM_name[$i])" -generation "($VM.gen[$i])" -memorystartupbytes "$(VM_list.mem[$i])";
Set-VMHardDiskDrive -VMName "($VM.VM_name[$i])" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI;
Set-VMMemory "($VM.VM_name[$i])" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem;
Set-VM -Name "($VM.VM_name[$i])" -ProcessorCount "($VM_cpus[$i])"
}
if ( ($VM.VM_name[$i]) -Like "CLI*") {
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1;
$DriveLetter = $Lettre.DriveLetter;
$drive = $DriveLetter + ":";
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-Win10.xml" -Destination "$Drive\Windows\Panther\Unattend.xml";
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd";
mkdir "${drive}:\Program Files\BGINFO";
Copy-Item "${env:soft_path}"BGInfo_Deploiement\BGInfo.exe "${drive}\Program Files\BGINFO";
Copy-Item "${env:soft_path}"BGInfo_Deploiement\mescouilles2.bgi "${drive}\Program Files\BGINFO";
Copy-Item "${env:soft_path}"BGInfo_Deploiement\bginfox86.bat "${drive}\Users\AdminLocal\AppData\Roaming\Microsoft\Windows\Start Menu\Programs\Startup";
}
Dismount-VHD "$env:VHD_PATH$vm_name.vhdx";
New-VM -Name "($VM_list.VM_name[$i])" -generation "($VM_list.gen[$i])" -memorystartupbytes "$(VM_list.mem[$i])";
Set-VMHardDiskDrive -VMName "($VM_list.VM_name[$i])" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI;
Set-VMMemory "($VM_list.VM_name[$i])" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem;
Set-VM -Name "($VM_list.VM_name[$i])" -ProcessorCount "($VM_list_cpus[$i])"
New-VM -Name "($VM.VM_name[$i])" -generation "($VM.gen[$i])" -memorystartupbytes "$(VM_list.mem[$i])";
Set-VMHardDiskDrive -VMName "($VM.VM_name[$i])" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI;
Set-VMMemory "($VM.VM_name[$i])" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem;
Set-VM -Name "($VM.VM_name[$i])" -ProcessorCount "($VM_cpus[$i])"
echo "Configuring adapters";
Rename-VMNetworkAdapter -VMName "($VM_list.VM_name[$i]) -NewName "($VM_list.switch_name[$i]);
Set-VMNetworkAdapter -VMName "($VM_list.VM_name[$i]) -Name "($VM_list.switch_name[$i]) -DeviceNaming on;
if ( ($VM_list.switch_name$j[$i]) -ne $null) {
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name2" -Name "Arc-SRV" -DeviceNaming on
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name3" -Name "WAN" -DeviceNaming on
Rename-VMNetworkAdapter -VMName "($VM.VM_name[$i])" -NewName "($VM.switch_name[$i])";
Set-VMNetworkAdapter -VMName "($VM.VM_name[$i])" -Name "($VM.switch_name[$i])" -DeviceNaming on;
while ( ("$VM.switch_name$j"[$i]) -ne $null) {
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name$j" -Name "$switch_name$j" -DeviceNaming on;
$j++
}
$i++
}
### Adding SRV-01
$vm_name = "SRV-01"
$switch_name = "Arc-SRV"
$gen = 2
$mem = 1024MB
$min_mem = 512MB
$max_mem = 2048MB
$cpus = 2
echo "Adding and configuring $vm_name"
cp "$env:BASE_VHD_PATH$env:BASE_SRV_NAME" "$env:VHD_PATH$vm_name.vhdx"
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1
$DriveLetter = $Lettre.DriveLetter
$drive = $DriveLetter + ":"
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory"
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml"
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd"
mkdir "${Driveletter}:\Tools\Scripts"
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1"
Dismount-VHD "$env:VHD_PATH$vm_name.vhdx"
New-VM -Name "$vm_name" -generation "$gen" -memorystartupbytes $mem
Set-VMHardDiskDrive -VMName "$vm_name" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI
Set-VMMemory "$vm_name" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem
Set-VM -Name "$vm_name" -ProcessorCount "$cpus"
echo "Configuring adapters"
Rename-VMNetworkAdapter -VMName "$vm_name" -NewName "$switch_name"
Set-VMNetworkAdapter -VMName "$vm_name" -Name "$switch_name" -DeviceNaming on
### Adding SRV-03
$vm_name = "SRV-01"
$switch_name = "Arc-SRV"
$gen = 2
$mem = 1024MB
$min_mem = 512MB
$max_mem = 2048MB
$cpus = 2
echo "Adding and configuring $vm_name"
cp "$env:BASE_VHD_PATH$env:BASE_SRV_NAME" "$env:VHD_PATH$vm_name.vhdx"
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1
$DriveLetter = $Lettre.DriveLetter
$drive = $DriveLetter + ":"
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory"
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml"
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd"
mkdir "${Driveletter}:\Tools\Scripts"
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1"
Dismount-VHD "$env:VHD_PATH$vm_name.vhdx"
New-VM -Name "$vm_name" -generation "$gen" -memorystartupbytes $mem
Set-VMHardDiskDrive -VMName "$vm_name" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI
Set-VMMemory "$vm_name" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem
Set-VM -Name "$vm_name" -ProcessorCount "$cpus"
echo "Configuring adapters"
Rename-VMNetworkAdapter -VMName "$vm_name" -NewName "$switch_name"
Set-VMNetworkAdapter -VMName "$vm_name" -Name "$switch_name" -DeviceNaming on
### Adding and configuring RTR-01
$vm_name = "RTR-01"
$switch_name = "Arc-CLI"
$switch_name2 = "Arc-SRV"
$switch_name3 = "WAN"
$gen = 2
$mem = 1024MB
$min_mem = 512MB
$max_mem = 2048MB
$cpus = 2
echo "Adding and configuring $vm_name"
cp "$env:BASE_VHD_PATH$env:BASE_SRV_NAME" "$env:VHD_PATH$vm_name.vhdx"
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1
$DriveLetter = $Lettre.DriveLetter
$drive = "$DriveLetter" + ":"
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory"
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml"
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd"
mkdir "${Driveletter}:\Tools\Scripts"
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1"
Dismount-VHD "$env:VHD_PATH$vm_name.vhdx"
New-VM -Name "$vm_name" -generation "$gen" -memorystartupbytes $mem
Set-VMHardDiskDrive -VMName "$vm_name" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI
Set-VMMemory "$vm_name" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem
Set-VM -Name "$vm_name" -ProcessorCount "$cpus"
echo "Configuring adapters"
Rename-VMNetworkAdapter -VMName "$vm_name" -NewName "$switch_name"
Set-VMNetworkAdapter -VMName "$vm_name" -Name "$switch_name" -DeviceNaming on
echo "Configuring adapters"
Rename-VMNetworkAdapter -VMName "$vm_name" -NewName "$switch_name"
Set-VMNetworkAdapter -VMName "$vm_name" -Name "$switch_name" -DeviceNaming on
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name2" -Name "Arc-SRV" -DeviceNaming on
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name3" -Name "WAN" -DeviceNaming on
# RTR-02
$vm_name = "RTR-02"
$switch_name = "Bou-LAN"
$switch_name2 = "WAN"
$gen = 2
$mem = 1024MB
$min_mem = 512MB
$max_mem = 2048MB
$cpus = 2
echo "Adding and configuring $vm_name"
cp "$env:BASE_VHD_PATH$env:BASE_SRV_NAME" "$env:VHD_PATH$vm_name.vhdx"
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1
$DriveLetter = $Lettre.DriveLetter
$drive = $DriveLetter + ":"
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory"
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml"
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd"
mkdir "${Driveletter}:\Tools\Scripts"
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1"
Dismount-VHD "$env:VHD_PATH$vm_name.vhdx"
New-VM -Name "$vm_name" -generation "$gen" -memorystartupbytes $mem
Set-VMHardDiskDrive -VMName "$vm_name" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI
Set-VMMemory "$vm_name" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem
Set-VM -Name "$vm_name" -ProcessorCount "$cpus"
echo "Configuring adapters"
Rename-VMNetworkAdapter -VMName "$vm_name" -NewName "$switch_name"
Set-VMNetworkAdapter -VMName "$vm_name" -Name "$switch_name" -DeviceNaming on
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name2" -Name "$switch_name2" -DeviceNaming on
# RTR-03
$vm_name = "RTR-03"
$switch_name = "Aston"
$switch_name3 = "WAN"
$gen = 2
$mem = 1024MB
$min_mem = 512MB
$max_mem = 2048MB
$cpus = 2
echo "Adding and configuring $vm_name"
cp "$env:BASE_VHD_PATH$env:BASE_SRV_NAME" "$env:VHD_PATH$vm_name.vhdx"
$Lettre = Mount-VHD -Path $env:VHD_PATH$vm_name.VHDx -PassThru | Get-Disk | Get-Partition | Get-Volume | Sort-Object -Property Size -Descending | Select-Object -First 1
$DriveLetter = $Lettre.DriveLetter
$drive = $DriveLetter + ":"
New-Item -Path "${Driveletter}:\conf\" -Name "Base" -ItemType "directory"
Copy-Item "${env:SCRIPTS_PATH}Unattend\FullUnattend-srv.xml" -Destination "$Drive\Windows\Panther\Unattend.xml"
Copy-Item "${env:SCRIPTS_PATH}deploy.cmd" -Destination "${Drive}\conf\deploy.cmd"
mkdir "${Driveletter}:\Tools\Scripts"
Copy-item "${env:SCRIPTS_PATH}Guests\$vm_name.ps1" "${Drive}\Tools\scripts\boot.ps1"
Dismount-VHD $env:VHD_PATH$vm_name.vhdx
New-VM -Name "$vm_name" -generation "$gen" -memorystartupbytes $mem
Set-VMHardDiskDrive -VMName "$vm_name" -Path "$env:VHD_PATH$vm_name.vhdx" -ControllerType SCSI
Set-VMMemory "$vm_name" -DynamicMemoryEnabled $true -MinimumBytes $min_mem -StartupBytes $mem -MaximumBytes $max_mem
Set-VM -Name "$vm_name" -ProcessorCount "$cpus"
echo "Configuring adapters"
Rename-VMNetworkAdapter -VMName "$vm_name" -NewName "$switch_name"
Set-VMNetworkAdapter -VMName "$vm_name" -Name "$switch_name" -DeviceNaming on
Add-VMNetworkAdapter -VMName "$vm_name" -SwitchName "$switch_name2" -Name "$switch_name2" -DeviceNaming on
### Starting VMS
echo "Starting VMs"

View File

@ -6,5 +6,5 @@
"RTR-02","Bou-LAN","WAN","","2","512","1024","2048","2"
"RTR-03","WAN","Aston","","2","512","1024","2048","2"
"CLI-01","Arc-CLI","","","1","512","512","1024","2"
"CLI-01","Arc-CLI","","","1","512","512","1024","2"
"CLI-02","Arc-CLI","","","1","512","512","1024","2"
"CLI-03","Bou-LAN","","","1","512","512","1024","2"

1 VM_name swith_name switch_name2 switch_name3 gen min_mem mem max_mem cpus
6 RTR-02 Bou-LAN WAN 2 512 1024 2048 2
7 RTR-03 WAN Aston 2 512 1024 2048 2
8 CLI-01 Arc-CLI 1 512 512 1024 2
9 CLI-01 CLI-02 Arc-CLI 1 512 512 1024 2
10 CLI-03 Bou-LAN 1 512 512 1024 2